{"product_id":"ge-is2020jpdbg01-power-distribution-board","title":"GE IS2020JPDBG01 - Power Distribution Board","description":"\u003ch3 data-start=\"0\" data-end=\"22\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cul data-start=\"23\" data-end=\"275\"\u003e\n\u003cli data-start=\"23\" data-end=\"57\"\u003e\n\u003cp data-start=\"25\" data-end=\"57\"\u003e\u003cstrong data-start=\"25\" data-end=\"41\"\u003ePart Number:\u003c\/strong\u003e IS2020JPDBG01\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"58\" data-end=\"101\"\u003e\n\u003cp data-start=\"60\" data-end=\"101\"\u003e\u003cstrong data-start=\"60\" data-end=\"77\"\u003eManufacturer:\u003c\/strong\u003e General Electric (GE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"102\" data-end=\"126\"\u003e\n\u003cp data-start=\"104\" data-end=\"126\"\u003e\u003cstrong data-start=\"104\" data-end=\"115\"\u003eSeries:\u003c\/strong\u003e Mark VIe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"127\" data-end=\"173\"\u003e\n\u003cp data-start=\"129\" data-end=\"173\"\u003e\u003cstrong data-start=\"129\" data-end=\"146\"\u003eProduct Type:\u003c\/strong\u003e Power Distribution Board\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"174\" data-end=\"275\"\u003e\n\u003cp data-start=\"176\" data-end=\"275\"\u003e\u003cstrong data-start=\"176\" data-end=\"192\"\u003eApplication:\u003c\/strong\u003e Designed for use in GE Distributed Control Systems within the Mark VIe platform.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"277\" data-end=\"297\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"298\" data-end=\"797\"\u003e\n\u003cli data-start=\"298\" data-end=\"334\"\u003e\n\u003cp data-start=\"300\" data-end=\"334\"\u003e\u003cstrong data-start=\"300\" data-end=\"329\"\u003eNumber of Input Channels:\u003c\/strong\u003e 24\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"335\" data-end=\"371\"\u003e\n\u003cp data-start=\"337\" data-end=\"371\"\u003e\u003cstrong data-start=\"337\" data-end=\"366\"\u003eNumber of Relay Channels:\u003c\/strong\u003e 12\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"372\" data-end=\"409\"\u003e\n\u003cp data-start=\"374\" data-end=\"409\"\u003e\u003cstrong data-start=\"374\" data-end=\"399\"\u003eTrip Solenoid Rating:\u003c\/strong\u003e 125 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"410\" data-end=\"439\"\u003e\n\u003cp data-start=\"412\" data-end=\"439\"\u003e\u003cstrong data-start=\"412\" data-end=\"421\"\u003eSpan:\u003c\/strong\u003e -8 mV to +45 mV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"440\" data-end=\"476\"\u003e\n\u003cp data-start=\"442\" data-end=\"476\"\u003e\u003cstrong data-start=\"442\" data-end=\"467\"\u003ePower Supply Voltage:\u003c\/strong\u003e 28 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"477\" data-end=\"511\"\u003e\n\u003cp data-start=\"479\" data-end=\"511\"\u003e\u003cstrong data-start=\"479\" data-end=\"497\"\u003eVoltage Range:\u003c\/strong\u003e 18 – 32 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"512\" data-end=\"547\"\u003e\n\u003cp data-start=\"514\" data-end=\"547\"\u003e\u003cstrong data-start=\"514\" data-end=\"527\"\u003eMounting:\u003c\/strong\u003e DIN-rail mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"548\" data-end=\"581\"\u003e\n\u003cp data-start=\"550\" data-end=\"581\"\u003e\u003cstrong data-start=\"550\" data-end=\"565\"\u003eTechnology:\u003c\/strong\u003e Surface mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"582\" data-end=\"627\"\u003e\n\u003cp data-start=\"584\" data-end=\"627\"\u003e\u003cstrong data-start=\"584\" data-end=\"610\"\u003eOperating Temperature:\u003c\/strong\u003e 40 °C to 70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"628\" data-end=\"659\"\u003e\n\u003cp data-start=\"630\" data-end=\"659\"\u003e\u003cstrong data-start=\"630\" data-end=\"639\"\u003eSize:\u003c\/strong\u003e 168 x 150 x 55 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"660\" data-end=\"689\"\u003e\n\u003cp data-start=\"662\" data-end=\"689\"\u003e\u003cstrong data-start=\"662\" data-end=\"678\"\u003eRepair Time:\u003c\/strong\u003e 3–7 days\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"690\" data-end=\"720\"\u003e\n\u003cp data-start=\"692\" data-end=\"720\"\u003e\u003cstrong data-start=\"692\" data-end=\"709\"\u003eAvailability:\u003c\/strong\u003e In Stock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"721\" data-end=\"761\"\u003e\n\u003cp data-start=\"723\" data-end=\"761\"\u003e\u003cstrong data-start=\"723\" data-end=\"745\"\u003eCountry of Origin:\u003c\/strong\u003e United States\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"762\" data-end=\"797\"\u003e\n\u003cp data-start=\"764\" data-end=\"797\"\u003e\u003cstrong data-start=\"764\" data-end=\"785\"\u003eManual Reference:\u003c\/strong\u003e GEH-6721L\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"799\" data-end=\"827\"\u003eFunctional Description\u003c\/h3\u003e\n\u003cul data-start=\"828\" data-end=\"1753\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-start=\"828\" data-end=\"948\"\u003e\n\u003cp data-start=\"830\" data-end=\"948\"\u003eThe IS2020JPDBG01 is a power distribution board designed for \u003cstrong data-start=\"891\" data-end=\"945\"\u003eAC power regulation, supervision, and distribution\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"949\" data-end=\"1018\"\u003e\n\u003cp data-start=\"951\" data-end=\"1018\"\u003eIncludes \u003cstrong data-start=\"960\" data-end=\"980\"\u003etwo line filters\u003c\/strong\u003e and an \u003cstrong data-start=\"988\" data-end=\"1015\"\u003eIS200JPDB circuit board\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1019\" data-end=\"1117\"\u003e\n\u003cp data-start=\"1021\" data-end=\"1117\"\u003eProvides \u003cstrong data-start=\"1030\" data-end=\"1071\"\u003etwo separate AC distribution circuits\u003c\/strong\u003e, each rated for \u003cstrong data-start=\"1088\" data-end=\"1114\"\u003e20 A at 115 or 230 VAC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1118\" data-end=\"1234\"\u003e\n\u003cp data-start=\"1120\" data-end=\"1234\"\u003eTo avoid PPDA alerts when only one AC power source is available, the input circuits should be wired in parallel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1235\" data-end=\"1338\"\u003e\n\u003cp data-start=\"1237\" data-end=\"1338\"\u003eEach circuit contains \u003cstrong data-start=\"1259\" data-end=\"1279\"\u003eone fused output\u003c\/strong\u003e and \u003cstrong data-start=\"1284\" data-end=\"1335\"\u003ethree fused and switched branch circuit outputs\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1339\" data-end=\"1416\"\u003e\n\u003cp data-start=\"1341\" data-end=\"1416\"\u003eOffers a connection for an \u003cstrong data-start=\"1368\" data-end=\"1413\"\u003eoptional JPDF 125 VDC distribution module\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1417\" data-end=\"1478\"\u003e\n\u003cp data-start=\"1419\" data-end=\"1478\"\u003eEquipped with \u003cstrong data-start=\"1433\" data-end=\"1475\"\u003estatus feedback for all fused circuits\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1479\" data-end=\"1542\"\u003e\n\u003cp data-start=\"1481\" data-end=\"1542\"\u003eProvides \u003cstrong data-start=\"1490\" data-end=\"1521\"\u003epassive monitoring circuits\u003c\/strong\u003e for AC magnitudes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1543\" data-end=\"1645\"\u003e\n\u003cp data-start=\"1545\" data-end=\"1645\"\u003e\u003cstrong data-start=\"1545\" data-end=\"1562\"\u003eConnector P1:\u003c\/strong\u003e Enables cable connection to a board containing a power diagnostic PPDA I\/O pack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1646\" data-end=\"1753\" data-is-last-node=\"\"\u003e\n\u003cp data-start=\"1648\" data-end=\"1753\" data-is-last-node=\"\"\u003e\u003cstrong data-start=\"1648\" data-end=\"1665\"\u003eConnector P2:\u003c\/strong\u003e Allows monitoring signals from other power distribution system cards to pass through.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":51002025640247,"sku":"IS2020JPDBG01","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0798\/8343\/6343\/files\/IS2020JPDBG01.jpg?v=1756216513","url":"https:\/\/www.controltech-supply.com\/sr\/products\/ge-is2020jpdbg01-power-distribution-board","provider":"ControlTech Supply Limited","version":"1.0","type":"link"}