{"product_id":"ge-ic660bba101-rtd-input-block-6-channels","title":"GE IC660BBA101 RTD Input Block 6 Channels","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE IC660BBA101 is a \u003cstrong\u003eRTD input block\u003c\/strong\u003e from the Genius I\/O series with six (6) input channels organized in three groups of two. It accepts platinum, nickel, and copper RTDs and delivers \u003cstrong\u003e0.1°C input resolution\u003c\/strong\u003e with factory calibration per channel group. Powered from 115 VAC or 125 VDC, the block reports temperature data over the Genius bus for distributed temperature monitoring in process and machinery applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInputs:\u003c\/strong\u003e 6 RTD channels, 3 groups of 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTD Types:\u003c\/strong\u003e Platinum, nickel, or copper RTDs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Resolution:\u003c\/strong\u003e 0.1°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration:\u003c\/strong\u003e Factory calibration per group\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlock Power:\u003c\/strong\u003e 115 VAC \/ 125 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 93-132 VAC \/ 105-145 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat Dissipation:\u003c\/strong\u003e 7 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 8.83 x 3.34 x 3.91 in (22.44 x 8.48 x 9.93 cm); weight 4 lbs (1.8 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Terminal Assembly:\u003c\/strong\u003e IC660TBA101\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Electronic Assembly:\u003c\/strong\u003e IC660EBA101\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-material RTD support:\u003c\/strong\u003e Accepts platinum, nickel, and copper RTDs to cover standard industrial temperature sensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh resolution:\u003c\/strong\u003e 0.1°C input resolution captures fine temperature variations for precise process control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory calibrated groups:\u003c\/strong\u003e Each two-channel group is factory calibrated, reducing field setup time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual power option:\u003c\/strong\u003e Operates from either 115 VAC or 125 VDC block power for flexible plant power architectures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenius bus integration:\u003c\/strong\u003e Reports temperature data to Series 90-30\/90-70 and other Genius bus masters as a stand-alone remote I\/O node.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrouped isolation:\u003c\/strong\u003e Three isolated channel pairs simplify mixed-circuit wiring and improve noise immunity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many RTD inputs does the IC660BBA101 provide?\u003c\/strong\u003e A: Six channels arranged as three isolated groups of two.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which RTD types are supported?\u003c\/strong\u003e A: Platinum, nickel, and copper resistance temperature detectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the measurement resolution?\u003c\/strong\u003e A: 0.1°C with factory calibration per channel group.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What power supply does it need?\u003c\/strong\u003e A: Block power of 115 VAC or 125 VDC, operating within 93-132 VAC \/ 105-145 VDC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDe-energize the block power supply and verify zero voltage before wiring.\u003c\/li\u003e\n\u003cli\u003eMount the block and set the Genius bus address and baud rate on the configuration switches.\u003c\/li\u003e\n\u003cli\u003eConnect the RTDs to the terminal assembly according to the group wiring diagram, observing lead compensation requirements.\u003c\/li\u003e\n\u003cli\u003eApply 115 VAC or 125 VDC block power and bond the chassis ground.\u003c\/li\u003e\n\u003cli\u003eEnergize and confirm the Unit OK and I\/O Enabled LEDs, then validate each channel's reading against a known temperature reference via the hand-held monitor.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSelect the IC660BBA101 for 115 VAC \/ 125 VDC-powered RTD applications; for 24\/48 VDC-powered installations choose the IC660BBA021.\u003c\/li\u003e\n\u003cli\u003eVerify RTD element type and wiring configuration (2\/3\/4-wire) match the terminal assembly instructions.\u003c\/li\u003e\n\u003cli\u003eFor thermocouple inputs, select the IC660BBA103 (115 VAC\/125 VDC) instead.\u003c\/li\u003e\n\u003cli\u003eOrder the IC660EBA101 electronic assembly and IC660TBA101 terminal assembly as spares for modular maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":53293023559991,"sku":"IC660BBA101","price":178.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0798\/8343\/6343\/files\/IC660BBA101_2.jpg?v=1791512054","url":"https:\/\/www.controltech-supply.com\/products\/ge-ic660bba101-rtd-input-block-6-channels","provider":"ControlTech Supply Limited","version":"1.0","type":"link"}