{"product_id":"ge-energy-is200shrah2a-mark-vie-hart-enabled-analog-input-output-board","title":"GE Energy IS200SHRAH2A Mark VIe HART Enabled Analog Input\/Output Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Energy IS200SHRAH2A\u003c\/strong\u003e is a HART-enabled analog Input\/Output (I\/O) terminal board designed for the GE Mark VIe control system series. It provides essential signal interfacing between field transmitters, actuators, and the corresponding \u003cstrong\u003ePHRA\u003c\/strong\u003e or \u003cstrong\u003eYHRA\u003c\/strong\u003e I\/O packs within the Mark VIe architecture. The board accepts up to ten analog inputs and two analog outputs, enabling bidirectional digital communication over standard 4–20 mA analog current loops via the HART (Highway Addressable Remote Transducer) protocol.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eIS200SHRAH2A\u003c\/strong\u003e interfaces with the \u003cstrong\u003ePHRA\u003c\/strong\u003e I\/O pack through a high-density 62-pin D-type connector. Ethernet communication is used to transmit signal data and diagnostics from the I\/O pack to the main Mark VIe controller assembly. Designed for high-density panel integration, the board supports DIN rail mounting and utilizes a plastic holder housed within a sheet metal carrier to protect internal electronics and maintain mechanical stability in industrial environments.\u003c\/p\u003e\n\u003cp\u003eFor flexible field adaptation, the \u003cstrong\u003eIS200SHRAH2A\u003c\/strong\u003e includes 20 hardware jumpers. Each jumper is clearly labeled with a designator and assigned a factory-specified function, allowing hardware configuration for voltage or current input selection as well as return-to-common connection settings. The board features conformal coating (Functional Revision A) to protect against environmental contaminants, dust, and moisture in harsh operating conditions.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHART Digital Communication:\u003c\/strong\u003e Enables full HART protocol pass-through over 4–20 mA current loops for two-way field device calibration, asset management, and diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density Analog Interfacing:\u003c\/strong\u003e Supports ten total analog inputs and two analog outputs on a single compact terminal board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMark VIe I\/O Pack Integration:\u003c\/strong\u003e Features a 62-pin D-type connector engineered for direct interfacing with GE Mark VIe PHRA and YHRA I\/O packs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomizable Field Jumpers:\u003c\/strong\u003e Incorporates 20 individually labeled jumpers to configure signal types (voltage\/current) and loop return paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged Mechanical Design:\u003c\/strong\u003e Built with a sheet metal carrier and plastic holder for DIN rail mounting, ensuring mechanical protection and vibration resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformal Coating:\u003c\/strong\u003e Functional revision A includes conformal coating to safeguard printed circuit board components against industrial environmental exposure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density Wiring Headers:\u003c\/strong\u003e Equipped with right-angle headers compatible with Euro-block terminal strips for simple field wiring and maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTurbine Control Systems:\u003c\/strong\u003e Interfacing field transmitters and control valves with GE Mark VIe control platforms in steam and gas turbine power plants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHART Transmitter \u0026amp; Valve Integration:\u003c\/strong\u003e Connecting smart instruments (pressure, temperature, flow, and level) requiring digital HART diagnostics to centralized DCS networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimplex Control Architectures:\u003c\/strong\u003e Serving as a dedicated analog I\/O interface point in simplex Mark VIe control cabinet configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Energy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003eIS200SHRAH2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark VIe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Acronym\u003c\/td\u003e\n\u003ctd\u003eSHRA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Description\u003c\/td\u003e\n\u003ctd\u003eHART Enabled Analog Input\/Output Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Revision\u003c\/td\u003e\n\u003ctd\u003eRevision A (Functional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Topology Support\u003c\/td\u003e\n\u003ctd\u003eSimplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCB Coating\u003c\/td\u003e\n\u003ctd\u003eConformal Coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Strategy\u003c\/td\u003e\n\u003ctd\u003eDIN Rail Mounting (with sheet metal carrier and plastic holder)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eInput \/ Output \u0026amp; HART Signals\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e10 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e2 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Signal Channels\u003c\/td\u003e\n\u003ctd\u003e12 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol Support\u003c\/td\u003e\n\u003ctd\u003eHART (Highway Addressable Remote Transducer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible I\/O Packs\u003c\/td\u003e\n\u003ctd\u003ePHRA I\/O Pack, YHRA I\/O Pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterfacing Connector\u003c\/td\u003e\n\u003ctd\u003e62-pin D-type connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Wiring Connection\u003c\/td\u003e\n\u003ctd\u003eHigh-density right-angle Euro-block headers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Jumpers\u003c\/td\u003e\n\u003ctd\u003e20 labeled jumpers (Voltage\/Current selection, Return-to-Common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface \/ Connector\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e62-Pin D-Type Connector\u003c\/td\u003e\n\u003ctd\u003eConnects directly to the PHRA or YHRA Mark VIe I\/O Pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuro-Block Terminal Headers\u003c\/td\u003e\n\u003ctd\u003eAccepts field wiring for 10 analog inputs and 2 analog outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port (via I\/O Pack)\u003c\/td\u003e\n\u003ctd\u003eCommunicates processed signal and HART data to the Mark VIe controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Installation Inspection:\u003c\/strong\u003e Visually inspect the IS200SHRAH2A board for physical damage to the sheet metal carrier, Euro-block headers, or 62-pin D-type connector before installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Isolation:\u003c\/strong\u003e Ensure all power supplies feeding the Mark VIe I\/O cabinet and field signal loops are fully de-energized prior to mounting or wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting:\u003c\/strong\u003e Secure the assembly onto the standard DIN rail using its plastic holder and sheet metal carrier frame.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJumper Configuration:\u003c\/strong\u003e Set the 20 onboard hardware jumpers to match the signal requirements (voltage vs. current inputs, return-to-common connection) for each specific channel according to system loop drawings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring:\u003c\/strong\u003e Connect field transmitter and actuator lines to the high-density right-angle Euro-block terminal headers. Verify proper polarity and grounding\/shielding practices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Pack Attachment:\u003c\/strong\u003e Carefully align and mate the PHRA or YHRA I\/O pack onto the 62-pin D-type connector until fully seated and secured.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning Checks:\u003c\/strong\u003e Power up the system and verify channel communication, HART field device pass-through, and LED status indicators on the connected I\/O pack.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eReplacement Recommendations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Compatibility Check:\u003c\/strong\u003e Confirm that the existing installation uses a Mark VIe system with a 62-pin connection interface. The IS200SHRAH2A cannot be installed in older Mark VI systems due to connector pin-count differences (62-pin vs. 37-pin).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJumper Verification:\u003c\/strong\u003e Prior to installing a replacement IS200SHRAH2A board, record and replicate the exact position of all 20 jumpers from the original board to ensure signal compatibility with field devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware and I\/O Pack Handling:\u003c\/strong\u003e Ensure the attached PHRA or YHRA I\/O pack is offline before disconnecting it from the 62-pin D-type header to prevent potential signal disruption on active channels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the GE IS200SHRAH2A terminal board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe GE IS200SHRAH2A serves as a HART-enabled analog Input\/Output terminal board within the Mark VIe system. It interfaces ten analog inputs and two analog outputs from field instruments to PHRA or YHRA I\/O packs, supporting digital HART communication over standard analog loops.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IS200SHRAH2A be used as a direct replacement in older GE Mark VI systems? \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the board is not compatible with Mark VI systems. The IS200SHRAH2A uses a 62-pin D-type connector designed specifically for Mark VIe PHRA\/YHRA I\/O packs, whereas legacy Mark VI systems utilize 37-pin connectors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow are the analog signal types configured on the IS200SHRAH2A?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e The board features 20 labeled hardware jumpers. Engineers can manually position these jumpers to set individual channels for voltage or current inputs and to configure return-to-common connections according to project wiring requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat system redundancy configurations are supported by the IS200SHRAH2A? \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IS200SHRAH2A hardware design specifically supports simplex Mark VIe system topologies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat physical mounting and environmental protections are included with this board? \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe board includes a plastic holder and sheet metal carrier frame designed for DIN rail mounting. It also features conformal coating (Functional Revision A) on the PCB to protect components from moisture and atmospheric contamination.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":50986342678839,"sku":"IS200SHRAH2A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0798\/8343\/6343\/files\/IS200SHRAH2A.jpg?v=1789122451","url":"https:\/\/www.controltech-supply.com\/products\/ge-energy-is200shrah2a-mark-vie-hart-enabled-analog-input-output-board","provider":"ControlTech Supply Limited","version":"1.0","type":"link"}