{"product_id":"fc-bsdol-04uni-honeywell-sdol-output-range-setting-assembly","title":"FC-BSDOL-04UNI Honeywell SDOL Output Range Setting Assembly","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell FC-BSDOL-04UNI is a conformal-coated range-setting assembly for the Safety Manager SDOL loop-monitored digital output modules. It provides selectable current-sensing ranges for four output channels, allowing the system to match its lead-breakage monitoring level to the connected field load.\u003c\/p\u003e\n\u003cp\u003eThe assembly consists of a main BSDOL-04 section and 16 detachable range-setting sub-modules. The main section is installed on the programming connector (Px) of the I\/O backplane, while the selected sub-modules define the range for each channel.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specs\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: Honeywell\u003c\/li\u003e\n\u003cli\u003eModel: FC-BSDOL-04UNI\u003c\/li\u003e\n\u003cli\u003eProduct type: SDOL output range-setting assembly\u003c\/li\u003e\n\u003cli\u003eSystem: Honeywell Safety Manager\u003c\/li\u003e\n\u003cli\u003eChannel positions: 4\u003c\/li\u003e\n\u003cli\u003eSub-modules: 16 total, comprising 4 each of S, L, M and H types\u003c\/li\u003e\n\u003cli\u003eCompatible output module family: SDOL-04x\u003c\/li\u003e\n\u003cli\u003eInstallation point: Px programming connector on the I\/O backplane\u003c\/li\u003e\n\u003cli\u003eS range: Spare channel setting; 4.7 kΩ dummy-load resistor\u003c\/li\u003e\n\u003cli\u003eL range: 17–47 mA; 33 Ω current-sense resistor\u003c\/li\u003e\n\u003cli\u003eM range: 48–199 mA; 10 Ω current-sense resistor\u003c\/li\u003e\n\u003cli\u003eH range: 200 mA or higher; 2.2 Ω current-sense resistor\u003c\/li\u003e\n\u003cli\u003eCoating: Conformal-coated FC version\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProvides four independently selected output current-sensing ranges.\u003c\/li\u003e\n\u003cli\u003eSupports lead-breakage monitoring configuration for SDOL output circuits.\u003c\/li\u003e\n\u003cli\u003eIncludes spare-channel S settings to prevent unwanted lead-breakage detection on unused channels.\u003c\/li\u003e\n\u003cli\u003eUses detachable range-setting sections for channel-specific configuration.\u003c\/li\u003e\n\u003cli\u003eFor redundant SDOL-0424 configurations, Honeywell specifies one BSDOL-04UNI assembly for the redundant pair.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does FC-BSDOL-04UNI generate digital output signals?\u003c\/strong\u003e\u003cbr\u003eA: No. It is a range-setting assembly for the SDOL output system. The SDOL module performs the output function.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the purpose of the S range?\u003c\/strong\u003e\u003cbr\u003eA: The S setting is intended for spare SDOL channels. It uses a 4.7 kΩ dummy-load resistor to prevent lead-breakage detection on unused channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Where is the main section installed?\u003c\/strong\u003e\u003cbr\u003eA: The BSDOL-04 main section is placed on the Px programming connector of the I\/O backplane.\u003c\/p\u003e\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eVerify that the installed output module belongs to the compatible SDOL-04x family.\u003c\/li\u003e\n\u003cli\u003eIdentify the connected load current for each of the four output channels.\u003c\/li\u003e\n\u003cli\u003eSelect the correct S, L, M or H range-setting sub-module for each channel.\u003c\/li\u003e\n\u003cli\u003eInstall the BSDOL-04 main section on the designated Px programming connector.\u003c\/li\u003e\n\u003cli\u003eFit the selected range-setting sections in the corresponding channel positions. The top position represents channel 1, followed by channels 2, 3 and 4.\u003c\/li\u003e\n\u003cli\u003eCheck the channel configuration and lead-breakage monitoring status after installation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eSelection Tips\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm the installed SDOL output module type before ordering.\u003c\/li\u003e\n\u003cli\u003eChoose each channel range according to the actual field load current, not the nominal system voltage alone.\u003c\/li\u003e\n\u003cli\u003eUse the S setting for unused channels requiring suppression of lead-breakage detection.\u003c\/li\u003e\n\u003cli\u003eFor redundant installations, verify the number of range-setting assemblies required by the project configuration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53726204690743,"sku":"FC-BSDOL-04UNI","price":182.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0798\/8343\/6343\/files\/FC-BSDOL-04UNI_2_12448991-315e-40cc-96d6-31ef229f3b91.jpg?v=1795658394","url":"https:\/\/www.controltech-supply.com\/products\/fc-bsdol-04uni-honeywell-sdol-output-range-setting-assembly","provider":"Controlnex Supply Limited","version":"1.0","type":"link"}