{"product_id":"16-channel-gas-and-flame-input-fta-honeywell-fc-tsgas-1624","title":"16-Channel Gas and Flame Input FTA – Honeywell FC-TSGAS-1624","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell FC-TSGAS-1624 is a conformal-coated gas and flame detector input Field Termination Assembly (FTA) for the Safety Manager system. It interfaces field detector and transmitter wiring with the SAI-1620m safe high-density analog input module.\u003c\/p\u003e\n\u003cp\u003eThe assembly provides 16 current-input channels for gas and flame detector applications. Its input circuitry converts field current signals into voltage signals for the associated SAI-1620m module and distributes external transmitter power through fused circuits.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specs\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: Honeywell\u003c\/li\u003e\n\u003cli\u003eModel: FC-TSGAS-1624\u003c\/li\u003e\n\u003cli\u003eProduct type: Safe gas\/flame detector input FTA\u003c\/li\u003e\n\u003cli\u003eSystem: Honeywell Safety Manager\u003c\/li\u003e\n\u003cli\u003eInput channels: 16, with common 0 V\u003c\/li\u003e\n\u003cli\u003eInput current range: 0–25 mA\u003c\/li\u003e\n\u003cli\u003eInput resistance: 500 Ω ±5%\u003c\/li\u003e\n\u003cli\u003eOutput to SAI-1620m: 0–4 V DC\u003c\/li\u003e\n\u003cli\u003eOutput accuracy: 0.1%\u003c\/li\u003e\n\u003cli\u003eExternal supply: 24 V DC\u003c\/li\u003e\n\u003cli\u003ePower consumption: 3 mA without field loads\u003c\/li\u003e\n\u003cli\u003eChannel fuse: 500 mA, 5 × 20 mm\u003c\/li\u003e\n\u003cli\u003eDimensions: 225 × 70 × 60 mm\u003c\/li\u003e\n\u003cli\u003eMounting rail: TS32 \/ TS35 × 7.5\u003c\/li\u003e\n\u003cli\u003eUsed rail length: 226 mm\u003c\/li\u003e\n\u003cli\u003eField wiring: Screw terminals, maximum 2.5 mm² conductor size\u003c\/li\u003e\n\u003cli\u003eTerminal strip length: 7 mm\u003c\/li\u003e\n\u003cli\u003eTerminal tightening torque: 0.5 Nm\u003c\/li\u003e\n\u003cli\u003eCoating: Conformal-coated FC version\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProvides 16 field connection channels for gas and flame detector current signals.\u003c\/li\u003e\n\u003cli\u003eSupports 0–20 mA signal input and conversion to the 0–4 V DC range used by SAI-1620m.\u003c\/li\u003e\n\u003cli\u003eProvides fused 24 V DC transmitter power distribution.\u003c\/li\u003e\n\u003cli\u003eIncludes a ground terminal for each channel to support analog input cable shielding.\u003c\/li\u003e\n\u003cli\u003eSupports both two-wire transmitters and three-wire gas\/flame detector connections when wired according to the approved application diagram.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which Safety Manager module works with FC-TSGAS-1624?\u003c\/strong\u003e\u003cbr\u003eA: The Honeywell hardware reference specifies the SAI-1620m safe high-density analog input module as its associated I\/O module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is FC-TSGAS-1624 itself a gas detector?\u003c\/strong\u003e\u003cbr\u003eA: No. It is a field termination assembly that connects gas\/flame detector or transmitter wiring to the Safety Manager input system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does it support HART communication?\u003c\/strong\u003e\u003cbr\u003eA: The standard TSGAS-1624 is not identified as the HART version. The TSGASH series is listed separately for HART applications.\u003c\/p\u003e\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the installed I\/O module is SAI-1620m and that the project design specifies TSGAS-1624.\u003c\/li\u003e\n\u003cli\u003eMount the FTA on a compatible TS32 or TS35 × 7.5 DIN rail.\u003c\/li\u003e\n\u003cli\u003eConnect the system interconnection cable to the designated Safety Manager interface.\u003c\/li\u003e\n\u003cli\u003eConnect the external 24 V DC supply to terminals A and B and connect protective ground to the marked ground terminal.\u003c\/li\u003e\n\u003cli\u003eWire each field transmitter to its assigned channel using the Honeywell connection diagram. Observe the specified fuse and grounding arrangement.\u003c\/li\u003e\n\u003cli\u003eCheck polarity, common 0 V connections, cable shields and channel assignments before energizing the circuit.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eSelection Tips\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm that the application requires a 16-channel gas\/flame detector input FTA rather than a standard analog input FTA.\u003c\/li\u003e\n\u003cli\u003eVerify the associated SAI-1620m module and the required SICC interconnection cable.\u003c\/li\u003e\n\u003cli\u003eCheck whether the project requires the standard TSGAS-1624 or the HART-enabled TSGASH variant.\u003c\/li\u003e\n\u003cli\u003eConfirm field transmitter wiring, external 24 V supply and channel fuse requirements before replacement.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53726204526903,"sku":"FC-TSGAS-1624","price":223.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0798\/8343\/6343\/files\/FC-TSGAS-1624_2_118860f1-6618-49e6-ab27-b557390b9c75.jpg?v=1795658387","url":"https:\/\/www.controltech-supply.com\/products\/16-channel-gas-and-flame-input-fta-honeywell-fc-tsgas-1624","provider":"Controlnex Supply Limited","version":"1.0","type":"link"}