{"product_id":"bently-nevada-81410-01-expander-board-pwa","title":"Bently Nevada 81410-01 Expander Board PWA","description":"\u003ch3\u003e\n\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 81410-01 Expander Board PWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an internal printed wiring assembly used within Bently Nevada machinery protection and condition monitoring systems. It is designed to expand internal signal handling and interconnections for specific monitoring modules, supporting multi-channel vibration and machinery protection functions.\u003cbr\u003eThe board operates as an auxiliary expansion interface, working together with the main monitor circuit board to distribute signals, support channel processing, and maintain stable internal communication. As a non-standalone component, the 81410-01 relies on the host module for power, environmental protection, and system compliance, and is widely used in continuous-duty industrial monitoring applications such as turbines, compressors, pumps, and motors.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ PWA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e81410-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBoard Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExpander Board, Printed Wiring Assembly (PWA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal signal expansion and interconnection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada machinery monitoring systems (3300 \/ 3500 platform dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal mounting within monitor module housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupplied by host monitor module backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDerived from system logic rails (typically +5 VDC and auxiliary rails from host module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow-power board-level consumption (drawn from host module supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBoard-to-board connectors for internal signal routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–35 °C to +65 °C (as part of host module specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–40 °C to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 95% non-condensing (system dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed internal mounting via connectors and standoffs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConforms to the compliance of the host monitoring module (API 670 when installed in compliant systems)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal expansion board for vibration and machinery protection monitors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndustries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower generation, oil \u0026amp; gas, petrochemical, heavy industrial machinery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51503837446455,"sku":"81410-01","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0798\/8343\/6343\/files\/3300-16-12-01-03-00-00-00_746c57f1-a47a-4242-a3e0-0f7e2d627636.jpg?v=1766977370","url":"https:\/\/www.controltech-supply.com\/pl\/products\/bently-nevada-81410-01-expander-board-pwa","provider":"ControlTech Supply Limited","version":"1.0","type":"link"}