{"product_id":"power-supply-560psu01-rtu560-rack-power-supply-unit","title":"Power Supply 560PSU01 — RTU560 Rack Power Supply Unit","description":"\u003ch3\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e560PSU01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDC power supply unit\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned specifically for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB RTU560 racks\u003c\/strong\u003e. It converts a wide-range DC input into stable\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5 V DC and 24 V DC outputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto power control, communication, and I\/O modules within the RTU system.\u003c\/p\u003e\n\u003cp\u003eEngineered for continuous industrial operation, the 560PSU01 supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant power configurations\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein systems such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e560MPR03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e560SFR02\u003c\/strong\u003e, enhancing system availability and operational safety. Its galvanic isolation, reverse voltage protection, and short interruption tolerance ensure stable performance even under harsh electrical conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 … 220 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Tolerance Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–20% … +15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Interruption Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 50 ms at 0% Un; \u0026gt; 48 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Input Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 … 0.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStarting Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 A (50 µs – 1.5 ms, Class S1 per IEC 60870-4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF1 = 3.15 A T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Circuit Breaker\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlus lead protected by 10 A upstream breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReverse Voltage Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBetween primary and secondary circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Output Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e44.3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDerating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–2.5 % per Kelvin above 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eOutput U1 (Logic Supply)\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e5.1 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTolerance\u003c\/td\u003e\n\u003ctd\u003e5.0 … 5.3 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent (min.)\u003c\/td\u003e\n\u003ctd\u003e0.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent (max.)\u003c\/td\u003e\n\u003ctd\u003e5.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Ripple\u003c\/td\u003e\n\u003ctd\u003e≤ 30 mVpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eOutput U2 (Auxiliary Supply)\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTolerance\u003c\/td\u003e\n\u003ctd\u003e22.4 … 26.3 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent (min.)\u003c\/td\u003e\n\u003ctd\u003e0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent (max.)\u003c\/td\u003e\n\u003ctd\u003e0.7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Ripple\u003c\/td\u003e\n\u003ctd\u003e≤ 80 mVpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Conditions (Climatic)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C … 70 °C (EN 60068-2-14)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 … 95% (non-condensing, EN 60068-2-30)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51624073396535,"sku":"560PSU01","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0798\/8343\/6343\/files\/560PSU01.jpg?v=1769567779","url":"https:\/\/www.controltech-supply.com\/id\/products\/power-supply-560psu01-rtu560-rack-power-supply-unit","provider":"ControlTech Supply Limited","version":"1.0","type":"link"}