{"product_id":"bently-nevada-adre-208-p-data-acquisition-interface-unit-daiu","title":"Bently Nevada ADRE 208-P Data Acquisition Interface Unit (DAIU)","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada ADRE 208-P\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eportable multi-channel Data Acquisition Interface Unit (DAIU)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for use with the ADRE for Windows® condition monitoring system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIt supports both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edynamic signals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(vibration, velocity, and displacement probes) and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estatic inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(process transmitters), as well as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKeyphasor\/speed signals\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efield use\u003c\/strong\u003e, the unit can operate from AC mains or battery power, enabling on-site vibration analysis and machinery diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereal-time waveform display, spectrum analysis, and advanced filtering\u003c\/strong\u003e, making it suitable for condition monitoring, fault diagnostics, and data logging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePortable and rugged, the ADRE 208-P allows technicians to collect accurate data from rotating machinery in various industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eADRE 208-P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 16 simultaneous channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Input Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to ±25 V DC for general analog inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow-Pass Filter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–3 dB at 0.09 Hz for slow process variable inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy (typical, +25°C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.77% of input signal, ±0.28% full-scale for 100–600 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Accuracy (0–50°C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.49% of full-scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGap Voltage Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±3.5% of input signal, ±1.92% full-scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKeyphasor Input Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.01% ±1 rpm (12.5k–25k rpm range), resolution ±3.05 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 signal input connectors; max ±25 V DC protected to ±33.75 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver-Range Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoftware indicated at ≥98% of full-scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC 90–260 V, 47–64 Hz; output 30 V DC ±5% at 1.6 A; internal NiCd battery for Keyphasor mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36.8 cm × 35.6 cm × 12.7 cm (14.5 × 14 × 5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~10.5 kg without power supply, ~11.2 kg with power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard battery: 0–40°C; High-temp battery: 0–50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard battery: –20–40°C; High-temp battery: –30–50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard industrial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSampling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSynchronous: 128 samples\/rev max for speeds up to ~15,000 rpm; 32 samples\/rev for 30k–60k rpm; Asynchronous: 2.56× frequency span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTriggering Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual threshold, automatic (50% peak-to-peak), scheduled, or external contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMeets CE mark requirements for EMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51243603886391,"sku":"ADRE 208-P","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0798\/8343\/6343\/files\/2_8de710bd-529f-4fe2-96e8-0a9dd9c60e23.jpg?v=1761009486","url":"https:\/\/www.controltech-supply.com\/es\/products\/bently-nevada-adre-208-p-data-acquisition-interface-unit-daiu","provider":"ControlTech Supply Limited","version":"1.0","type":"link"}