{"product_id":"ge-ur8nv-analog-input-module","title":"GE UR8NV Analog Input Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE UR8NV\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an expansion\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eanalog input module\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003efor the Universal Relay (UR) series from GE Multilin (Vernova Grid Solutions). It provides high-accuracy acquisition of current signals (and in some implementations voltage via CT\/VT interface) for advanced protection, metering, automation, and control applications in power systems. The UR8NV integrates seamlessly into UR relay chassis to support substations, generators, transformers, motor protection schemes, and other critical electrical infrastructure. It offers reliable performance in industrial environments with rugged design, diagnostics features, and hot-swappable capability.\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"align-top\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth class=\"align-top\"\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUR8NV\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries \/ Platform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Multilin Universal Relay (UR) Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 CT channels (current transformer inputs)\u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated VT interface (secondary voltage range, standard)\u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard CT secondary (1 A or 5 A nominal)\u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSampling Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 48 samples per cycle per channel\u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDifferential and single-ended measurement support\u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 0.2 % (under rated conditions)\u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45–65 Hz\u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBurden Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 VA at 5 A (typical)\u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal channel fault detection \u0026amp; CT\/VT health monitoring\u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation between field wiring and internal circuitry\u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBackplane mount, hot-swappable within UR chassis\u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–40 °C to +70 °C (industry environments)\u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temp.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–40 °C to +85 °C\u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 kg (~1.32 lb) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":51684150772023,"sku":"UR8NV","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0798\/8343\/6343\/files\/IC695ALG600-DD_35f78145-be4d-458c-8b8e-114fcb4e3ff2.jpg?v=1771032511","url":"https:\/\/www.controltech-supply.com\/az\/products\/ge-ur8nv-analog-input-module","provider":"ControlTech Supply Limited","version":"1.0","type":"link"}